zwitschi d4af4af90f hero: make the portals real recesses and land the facade on Z 0
The portal detail shot failed for a modelling reason, not a camera reason: the
doors were 0.1 m panels on a solid plinth, so they read as shading. The plinth is
now four piers plus a lintel band, with a 1.2 m reveal, stone jambs and lintels
standing 0.10 m proud and three mullions per opening. review-06 frames them from
8 m at eye height.

Two defects fixed while doing it: the jamb boxes hung 0.15 m below the pavement,
so the facade imported with min Z -15 cm; and a rebuild run against a read-only
.blend silently skipped the save, which is why screenshots kept showing the old
geometry.
2026-11-07 12:46:00 +01:00
zwitschi 52a736bc9f review: drop two orphan shots left by the renamed camera list 2026-11-07 12:08:42 +01:00
zwitschi 0383eabc8e review: put the character on the floor, split the cubes, commit the shots
The review floor was a 5 cm slab centred 50 cm down, so the character floated
1.8 m above it. The floor is now 90 m x 90 m x 10 cm with its top face at Z 0 and
the character measures Z 0..83 cm - feet on the plane.

Two cubes only: A on the ground as the contact/scale reference, B held at 2 m so
its cast shadow separates from the body for comparison. The scale-cubes camera
was still aimed at the old three-cube row and now looks at both from the south.

Screenshots are committed per the owner's instruction, and .gitignore no longer
excludes them.
2026-11-07 12:02:18 +01:00